Skip to main content
academy eng

How to check the operating pressure of Promove Hammers

December 10, 2020

After setting the flow and pressure on the excavator with a flow meter, it is important to check the pressure at which the breaker is working. This can be done by connecting a manometer to the inlet line of the hammer while it is working. In case the value is different from the recommended one in the manual it is possible to act on the pressure valve located on the front side of the hammer to adjust the pressure.
-----------------
VALID FOR
xP800 / xP1000 / xP1200 / xP1500 / xP1700 / xP2000 / xP2400 / xP3100 / xp4500 / xP7000

On this website we use first or third-party tools that store small files (cookie) on your device. Cookies are normally used to allow the site to run properly (technical cookies), to generate navigation usage reports (statistics cookies) and to suitable advertise our services/products (profiling cookies). We can directly use technical cookies, but you have the right to choose whether or not to enable statistical and profiling cookies. Enabling these cookies, you help us to offer you a better experience. Cookie policy